Search results for "Background Correction"
showing 5 items of 5 documents
Cubic smoothing splines background correction in on-line liquid chromatography–Fourier transform infrared spectrometry
2010
A background correction method for the on-line coupling of gradient liquid chromatography and Fourier transform infrared spectrometry (LC-FTIR) is proposed. The developed approach applies univariate background correction to each variable (i.e. each wave number) individually. Spectra measured in the region before and after each peak cluster are used as knots to model the variation of the eluent absorption intensity with time using cubic smoothing splines (CSS) functions. The new approach has been successfully tested on simulated as well as on real data sets obtained from injections of standard mixtures of polyethylene glycols with four different molecular weights in methanol:water, 2-propano…
Recent advances in on-line liquid chromatography - infrared spectrometry (LC-IR)
2010
We review advances in isocratic and gradient liquid chromatography hyphenated on-line with infrared spectrometry (LC-IR). We place special emphasis on chemometric background correction and other applications of chemometric algorithms used to improve the sensitivity and the resolution of LC-IR signals. We also comment on recent technical advances, (e.g., dedicated flow-cells and new light sources) and review applications in the technological, cosmetics, environmental and food sectors.
Application of point-to-point matching algorithms for background correction in on-line liquid chromatography–Fourier transform infrared spectrometry …
2009
A new background correction method for the on-line coupling of gradient liquid chromatography and Fourier transform infrared spectrometry has been developed. It is based on the use of a point-to-point matching algorithm that compares the absorption spectra of the sample data set with those of a previously recorded reference data set in order to select an appropriate reference spectrum. The spectral range used for the point-to-point comparison is selected with minimal user-interaction, thus facilitating considerably the application of the whole method. The background correction method has been successfully tested on a chromatographic separation of four nitrophenols running acetonitrile (0.08…
Determination of critical eluent composition for polyethylenglycols using on-line liquid chromatography-Fourier transform infrared spectrometry.
2008
In this work, it has been extended to methanol:water mobile phases, the use of a background correction method for on-line LC-FTIR measurements named Univariate background correction based on the use of a reference spectra matrix (UBC-RSM) and absorbance ratios. It permits to overcome the problem related to spectral changes occurring during the gradient elution, which in the past limited the on-line coupling of LC and FTIR to isocratic elutions. The combined use of the aforementioned background correction technique in on-line isocratic and gradient LC-FTIR, and partial least squares (PLS) has been applied for the search of the critical conditions for polymers. Polyethylenglycol (PEG) has bee…
Prediction of the gene expression measure by means of a GLMM
2007
Microarrays permit to scientists the screening of thousands of genes simultaneously to determine, for example, whether those genes are active, hyperactive or silent in normal or cancerous tissues. A primary task in microarray analysis is to obtain a good measure of the gene expression that can be used for a so called higher level analysis. Different methods have been proposed for high density oligonucleotide arrays (see Cope et al. (2004) for a review). Aim of this paper is to obtain a new gene expression measure based on the background correction model proposed by Mineo et al. (2006). The proposed method is validated by means of a free available data-set called Spike-In133 experiment, wher…